Compact Pulsed Eddy Current Flaw Detector

The probe features an IP68-rated housing (dust and moisture protection) and can be used underwater
The device weighs just 0.8 kg. It features an ergonomic, impact-resistant housing and a color display with impact-resistant glass
The temperature of the metal of the test object is from -200 to +400°C. The temperature of insulation jacket surface in the area of probe placement is from -20 to +60°C


Applications of PE1537:
• Corrosion detection on oil and gas pipelines with film insulation;
• Corrosion detection on pipes and pipelines with a 3-layer polypropylene coating;
• Corrosion detection on stainless steel pipes and pipelines for the nuclear and chemical industries;
• Corrosion detection on pipes and pipelines in polyurethane foam insulation;
• Corrosion detection on different steel supports, for example, street lamp supports or electrical grid supports;
• Inspection of pipes with internal cement coating from the inside of the pipe;
• Corrosion areas detection on pipes through rust without stripping;
• Corrosion detection on steel ship parts through a thick layer of paint.
The device features:
• The device has the minimum size of a probe, so it can detect small defects;
• The device has a bright display which shows the measured thickness, A-scan and C-scan;
• Measurement results are stored in the device's memory and easily transferred to a PC via USB;
• The display is protected by shock-resistant glass;
• The probe features an IP68-rated housing and can be used underwater.
Technical specifications
The PE1537 PEC Flaw Detector
-
Range of measured thickness for steel0…30 mm
-
Average thickness measurement error10%
-
Range of insulation coating thickness (PEC153704 probe)– no jacket, stainless steel jacket: 0…200 mm
– aluminum jacket: 0…180 mm
– galvanized steel jacket: 0…150 mm
-
Range of insulation coating thickness (PEC153705 probe)– no jacket, stainless steel jacket: 0…200 mm
– aluminum jacket: 0…100 mm
-
Minimum diameter of the tested pipes89 mm
-
Temperature of the test object metal-200…+400°С
-
Temperature of the jacket surface in the place of probe contact-20…+60°С
-
Range of operating ambient temperature-20…+50°C
-
Time of continuous operation without battery recharging7 hours
-
Dimensions232 x 135 x 44 mm
-
Weight0.8 kg